• This cable is used for low voltage electrical distribution (0.6 / 1kV, 50Hz). The cable comprises a neutral messenger which is twisted with the rest of the conductors. One or several street light conductors are possible, consult us.
  • Tape

    1,00
    This tape is designed to conduct the electricty into the earth system and to guarantee the default current runoff. If the copper gives an important electrical and the tinned coating protects from theft thanks to the non visible copper coating conductivity. The copper bonded steel offers a good economical alternative to copper. Furthermore Galvanized steel is an economical solution to coppered tinned steel and protect from the theft too. It has a good conductivity.
  • Cable

    1,00
    This cable is used pour earth systems. It is available in bare copper or insulated copper.
  • The REMIC module type RRCP offers a network outlet that can be cut (400 A function) or protected using maximum 200A fuses 115mm size 2 (200A function). It is installed on the M12 standardised connection terminals of the sets of bars supports. It is mainly used for supplying a collective or individual service with supervised power.
  • The fuse service module exists in 3 versions: 60A, 90A and 100A available in single or three phase kits depending on the model. In variation of the fused neutral, a triple neutral is possible. It is installed on the M12 standardized connection terminals of the set of bars support. It is used to tap a single or three phase service connection ensuring protection through fuses size 00 (60A and 90A modules) or 22x58 (100A module). The multitap connection module comprises 1 neutral and 3 phases. It allows a maximum of 3 single phase or 3 three-phase services to be connected. It is installed on the M12 standardized connection terminals of the set of bars support. It is mainly used when the AD fuses are installed in the customer premises.
  • The network module is available in 2 versions: - 50-240mm², - 50-150mm². It comprises one neutral terminal and three phase terminals. It is installed on the M12 standardized connection terminals of the sets of bars supports.
  • The sets of bars supports 300, 450 and 600 respectively offer 6, 9 and 12 connection terminals for each pole.
  • The modular distribution box is designed to be equipped with devices that protect the customer installation. The 30 mA differential switches for two-phases are designed to protect persons by detecting insulation defects. The AC-type detected faults on the AC component. The A-type detected faults on the AC and DC components. The DC components faults can be produce by some electrical devices. The size of differntial swith is 2 modules. Subdivisional circuit breakers are designed to protect the circuits of the installation. The proposed materials are : - Neutral Phase 230V, - A type C trip curve according to EN 60898-1.
  • This end connectors range is used for the connection of leading in cables to electrical equipment terminals (cutouts, electronic meters, ect). It is a universal solution to connect the connection cable and the meter terminals no matter what is the metal or the block nature. They can be fitted on copper or aluminum stranded or solid core conductors.
  • This board is designed to accommodate the single phase electronic meter and the circuit-breaker. It defines the boundary between the energy distributor and the installer private domain. The cover is optional.
  • The box with 3 outlets is designed to establish up to 6 single phase connections or up to 3 three phase connections at one point of the low voltage aerial bundled network. The box with 7 outlets is designed to establish the junction of 2 overhead networks and the tap contact of 6 single phase or three phase connections maximum. These boxes can be installed on a façade or a pole. They can also be used at the network end.
  • The 8 service distribution box allows the junction of 2 aerial networks and the derivation of 8 single phase or 4 three phases connections maximum. This box can be fixed either on a facade or on a pole. It can be used as an accessory for network shutdown.
  • This product is designed to ensure watertightness at the end of a network cable and to connect home device with peripheral neutral service cable. No tool is required for the installation.
  • These AD fuse cartridges are used together with the circuit-breaker installed on the individual service tap connection. They perform the cutoff for high short-circuit currents and there by extend the service life of the associated circuit-breaker, which is not overloaded up to the limit.
  • This end connectors range is used for the connection of leading in cables to electrical equipment terminals (cutouts, electronic meters, ect). It is a universal solution to connect the connection cable and the meter terminals no matter what is the metal or the block nature. They can be fitted on copper or aluminum stranded or solid core conductors.
  • These low voltage fuses cartridges NH00, NH1 or NH2 are type gG. They are used as protection unit of the low voltage public electricity supply networks and works. It is installed in: - Low voltage switchboards of the public electricity supply substations, - Cutout boxes, inside or outside supply switches, - Switch cabinets for subsurface networks, - Metering boxes and cabinets for different uses
  • This mini-switch limits the current that can flow permanently through the connection to a certain intensity. It enables the customer's energy consumption to be controlled and limited to the subscribed power, providing excellent protection against fraud, mainly in the event of meter by-pass / shunt. Massive overconsumption due to fraud is significantly reduced.
  • The tool set U804 provides various tools required for the connection of the underground incoming and outgoing cables to the REMIC emergency junction box.
  • The cabinet is part of the installation check board. It ensures the connection individual principal cutout function. It is designed to receive fuse cartridges size 10.3x38, 14x51, 22x58 and DIN 00.
  • The protective duct is designed to protect aerial subsurface connections on poles or façades. It is fixed on pole using straps or on facade using screws.
  • This unipolar aerial pole allows to star one conductor into 8 outlets. The use of the 2 unipolar blocks enables to realize up to 8 singlephase connections. This bloc has a plate number to easily identify the conductor. The box can be installed on a facade or a pole.
  • The "C" shape connectors and jumper clamps are designed to connect two conductors. The mechanical and electrical connection is ensured thanks to crimping (U009) or thanks to a mechanical tightening wich can be removed (U020). The copper connector is designed to fix up an installation in case the conductor has been severed. The stainless steel fastening allows the product to be buried. The connector L260 is equipped with a shear head. The stainless steel kit comprises two tubular lugs (U030) as well as a nut and a bolt. It is designed to disconnect the earth system in order to perform earth resistance measurements. The cutting blade is designed to open the earth system during earth resistance measurements. It is rather used inside for a residential installation. The copper round terminal lug is used to connect bare copper conductors to copper terminals.
  • This end connectors range is used for the connection of leading in cables to electrical equipment terminals (cutouts, electronic meters, ect). It is a universal solution to connect the connection cable and the meter terminals no matter what is the metal or the block nature. The end connector can be fitted on sectoral or circular-shaped copper or aluminum stranded or solid core conductors. It provides class II protection using the double insulated colored tail, when equipped with the cover.
  • This stainless steel strap and this range of installation tools is designed to fix the suspension or anchoring clamp brackets on all types of poles (wooden, metal or concrete).