• This preinsulated sleeve is designed for the connection of stranded core aerial service cables (aluminium or copper) to aluminium solid core sub-surface service cables. It is also used to connect aluminium solid core service cables to one another. Cable sections up to 25mm² can be connected on the stranded core side and up to 35mm² on the solid core side.
  • This preinsulated sleeve is designed for the connection of low voltage overhead insulated conductors to other ones. The junction can be established between two conductors of equal or unequal sections. All combinations of sections are possible. The section of the cables ranges from 95mm² to 150mm². The neutral conductor is dimensioned to withstand tensile strength greater than 1 530daN for the 95mm² and greater than 2 500daN for the 150mm² section.
  • This preinsulated sleeve is designed for the connection of insulated conductors of a low voltage overhead network to other ones. The junction can be established between two conductors of equal or unequal sections. All combinations of sections are possible. The section of the cables ranges from 16mm² to 95mm². The neutral conductor is dimensioned to withstand tensile strength greater than 1 600daN for the 54mm² section and greater than 2 000daN for the 70mm² section.
  • This preinsulated sleeve is designed for the connection of copper or aluminium stranded core overhead insulated conductors with traction or with no mechanical load. It is used for the installation, repair or modification of low voltage service lines. The junction can be established between two conductors of equal or unequal sections. All combinations of sections are possible. The section of the cables ranges goes from 6 up to 35mm².
  • These preinslated lugs with mechanical tightening are used to connect aerial aluminum or copper conductors, solid or stranded round core, to copper equipment terminals. They are to be used without mechanical load. They are made of tinned copper which allows compatibility to copper and aluminium. The connection of the conductor is ensured by one or two shear head screws, for optimal tightening.
  • These preinslated lugs with mechanical tightening are used to connect aerial aluminum or copper conductors, solid or stranded round core, to copper equipment terminals. They are to be used without mechanical load. They are made of tinned copper which allows compatibility to copper and aluminium. The connection of the conductor is ensured by one or two shear head screws, for optimal tightening.
  • This preinsulated lug is designed to connect low voltage overhead insulated conductors to copper equipment terminals. The cable sections range from 16 to 150mm² for the spin-welded terminal lug and 16 to 150mm² for the crimped lug.
  • This mini-switch limits the current that can flow permanently through the connection to a certain intensity. It enables the customer's energy consumption to be controlled and limited to the subscribed power, providing excellent protection against fraud, mainly in the event of meter by-pass / shunt. Massive overconsumption due to fraud is significantly reduced.
  • This material made of hot dip galvanised steel is designed to fix anchoring and suspension clamps.
  • This material made of hot dip galvanised steel is designed to fix anchoring and suspension clamps.
  • These short and high shoes ensure protection against electrical and/or mechanical shocks.
  • This mat is used to protect the fitter working area from contact voltage, during electrical work, without load in HV context and under load in LV one. Several models are available from class 0 to class 4. The insulating ladder protects the fitter from current voltage during electrical installation works.
  • These equipment aim to protect hands during installation works. The insulating gloves are designed to protect against electrical shocks during powered works.
  • These equipment aim to protect the head and the face during installation works.
  • These equipment aim to protect the fitter from falls during installation works at height.
  • These parallel groove clamps are designed to connect a bare aluminium or copper line from another bare aluminium line. They are adapted to outdoor use.
  • This overhead swivel is used between two overhead pulling grips to replace an old conductor by a new one or between a pulling grip and the wire rope on the winch. It prevents any twisting of the conductor during pulling, unreeling and laying. All of the parts are made of alloyed steel. The overhead pulling grip is deasigned for the pulling, unreeling and larying of bare and insulated self-supporting overhead cables. This overhead pulling grip is deasigned for the pulling, unreeling and larying of bare and insulated overhead cables with neutral messenger.
  • These connectors are used to make a tap connection between aerial networks. The connection is realised by means of insulation piercing technology.
  • These connectors are used to make a tap connection between aerial networks. The connection is realised by means of insulation piercing technology.
  • This telescopic stick is used to operate a fuse switch disconnector, remotely from the ground level, but also to check that there is no voltage or for the earthing thanks to accessories sold apart. Each model is equipped with a notched universal U-shaped terminal end. To operate a Fuse Switch Disconnector (FSD) remotely from the ground level, the notched universal U-shaped threaded terminal end is fixed to the operating stick. The F210 end can be used to operate a Fuse Switch Disconnector manually, without loss of handling thanks to its handle shape.
  • The anchoring assembly is designed for the 1500daN single or double anchoring of A.B.C. (Aerial Bundled Conductors) with insulated neutral messenger of 54.6 and 70mm² sections. It comprises a bracket supporting one or two anchoring clamps. The suspension assembly is designed for suspending the low voltage A.B.C. (Aerial Bundled Conductors) with insulated neutral messenger of 50 - 95mm² sections for code K277 and 50 - 70mm² sections for code K283. It comprises a movable link system, a suspension clamp and a bracket. 2 standard suspension assemblies are available: - ES 1500, - ESF 715 equipped with a fuse element (breaking 715 ± 65daN). The fuse element can be factory calibrated between 500 and 1 200daN. It is designed to break when an abnormal effort is applied on the A.B.C. The cable drops without causing the pole to break (i.e.: tree falling on to a power line). The cable can be quickly put back in position thanks to the installation of a new clamp on the bracket still in place.
  • This sleeve is designed to connect aluminium or copper conductors. It does not need the sectoral cores to be rounded before. It is implemented using a 13 or 17mm spanner. The electrical capacity is respectively 240mm² aluminium conductors (K191, K192), 150mm² aluminium or copper conductors (K193) and 95mm² aluminium or copper conductors (K189).
  • This c onnector is de signed to connect a low voltage A.B.C. (Aerial Bundled Conductors) to another network of the same type or to a low voltage aluminium alloy or copper bare conductors network. In main line, the section of the insulated conductors is from 25 to 150mm² depending on the model, and is from 7 to 120mm² on bare conductors. In tap line, the section of the insulated conductors is from 25 to 70mm² and from 35 to 150mm² depending on the model.
  • This connector is designed to connect a low voltage A.B.C. (Aerial Bundled Conductors) network to another low voltage aluminium alloy or copper bare conductors network. The section of the bare conductors is from 7 to 240mm² depending on the model. The section of the insulated cables is from 25 to 150mm² depending on the model.
  • This connector is designed to connect a low voltage A.B.C. (Aerial Bundled Conductors) network to another network of the same type.
  • This connector is designed to connect from 2 to 4 insulated service conductors to the low voltage A.B.C. (Aerial Bundled Conductors).
  • The RING connector is designed to establish a tap connection on low voltage underground networks. It is installed inside an underground box. It is used on a main cable, with synthetic insulation, of type: - Circular or sectoral, - Copper or aluminium, - Solid or stranded core The underground box enables the tap connection from an underground network. It makes possible the tap connection of every conductors type (stranded, solid, multi-stranded, round or sectoral). It comprises the connector, the resin, the box and accessories according to the local standard.
  • The RING connector is designed to establish a tap connection on low voltage underground networks. It is installed inside an underground box. It is used on a main cable, with synthetic insulation, of type: - Circular or sectoral, - Copper or aluminium, - Solid or stranded core. The underground box enables the tap connection from an underground network. It makes possible the tap connection of every conductors type (stranded, solid, multi-stranded, round or sectoral). It comprises the connector, the resin, the box and accessories according to the local standard.
  • The RING connector is designed to establish a tap connection on low voltage underground networks. It is installed inside an underground box. It is used on a main cable, with synthetic insulation, of type: - Circular or sectoral, - Copper or aluminium, - Solid or stranded core. The underground box enables the tap connection from an underground network and for every conductors type (stranded, solid, multi-stranded, round or sectoral). It comprises the connector, the resin, the box and accessories according to the local standard.
  • The modular distribution box is designed to be equipped with devices that protect the customer installation. The 30 mA differential switches for two-phases are designed to protect persons by detecting insulation defects. The AC-type detected faults on the AC component. The A-type detected faults on the AC and DC components. The DC components faults can be produce by some electrical devices. The size of differntial swith is 2 modules. Subdivisional circuit breakers are designed to protect the circuits of the installation. The proposed materials are : - Neutral Phase 230V, - A type C trip curve according to EN 60898-1.
  • This board is designed to accommodate the single phase electronic meter and the circuit-breaker. It defines the boundary between the energy distributor and the installer private domain. The cover is optional.
  • This 2 outputs meter cabinet is a solution perfectly suitable for Rural Electrification (RE) and particularly Income Generating Activities (IGA's). It comprises an internal circuit breaker, a meter and a differential circuit breaker to ensure goods and people protection. It is equipped with an input through a large cable gland for power supply and 2 outputs: - An electrical outlet for simple access to energy, - Second outlet through a smaller cable gland and black domino terminal for home wiring. The whole set is pre-wired. Ideally, it can be installed inside the home or below a shelter.
  • The customer box is designed to receive a meter and the needed protection equipment. It can be installed outside or inside the house. The box is part of the control panel board. It is designed to fulfill the individual main branch circuit breaker. It is intended to receive a 22x58 fuse.
  • The anchoring assembly is used for single or double dead-ending of A.B.C (aerial bundled conductors) with insulated neutral messenger. Two different sections of neutral messenger are available: 54.6mm² and 70mm²
  • The anchoring assembly is used for single or double dead-ending of A.B.C (aerial bundled conductors) with insulated neutral messenger. Two different sections of neutral messenger are available: 54.6mm² and 70mm²
  • This product is designed to ensure watertightness at the end of a network cable and to connect home device with peripheral neutral service cable. No tool is required for the installation.