• The pulley is designed to receive low voltage A.B.C. (Aerial Bundled Conductors) for unwinding and pulling operations. The mechanical winch is designed to pull conductors of a low voltage power line. Light and small, it can be used for all types of cable adjustments, in particular on top of supports. It can be used also for lifting loads, stowing poles and other applications. The overhead comealong clamp is designed to pull, retain and stretch bare or insulated conductors of a power line. Three models are available according to the type of conductors to be implemented: - Bare steel or aluminium cable, - A.B.C. (Aerial Bundled Conductors) type neutral messenger, - A.B.C. type fully supported. The wire-strainer is designed to pull conductors on a low voltage electrical line manually. These climbers are designed to help fitters climbing along poles and facilitate work at height. Sold in pair.
  • The pulley is designed to receive low voltage A.B.C. (Aerial Bundled Conductors) for unwinding and pulling operations. The mechanical winch is designed to pull conductors of a low voltage power line. Light and small, it can be used for all types of cable adjustments, in particular on top of supports. It can be used also for lifting loads, stowing poles and other applications. The overhead comealong clamp is designed to pull, retain and stretch bare or insulated conductors of a power line. Three models are available according to the type of conductors to be implemented: - Bare steel or aluminium cable, - A.B.C. (Aerial Bundled Conductors) type neutral messenger, - A.B.C. type fully supported. The wire-strainer is designed to pull conductors on a low voltage electrical line manually. These climbers are designed to help fitters climbing along poles and facilitate work at height. Sold in pair.
  • These toolings are designed to realise connections.
  • Lugs

    1,00
    This spin-welded preinsulated lug is designed to connect low voltage overhead insulated conductors to copper equipment terminals. The cable sections range that the lug can receive goes from 16 to 150mm².
  • This cable is used for low voltage electrical distribution (0.6 / 1kV, 50Hz). The cable comprises a neutral messenger which is twisted with the rest of the conductors. One or several street light conductors are possible, consult us.
  • These anchoring and suspension clamps are designed to anchor and to hold the A.B.C. (Aerial Bundled Conductors) network. This range is rather designed to self-supporting cables. The suspension bracket is designed to fix clamps on a pole or a wall. The bracket fixing is performed by straps or screws. The hook is used to fix an anchoring clamp on a pole or a wall. It is implemented once holes are drilled.
  • The load limiter is provided with an electronic regulator which controls intensity and manages power automatically without user/operator intervention. It is perfectly suitable for flat fee invoicing. It replaces the meter and cancels the requirement of consumption reading. The cabinet can be installed at the top of the pole or on the outside facade with the help of screws and strap. The cabinet resists to UV and to water or insect penetration (IP34D). Its cover closing can be sealed providing an excellent fraud protection. This cabinet limiter can receive a single phase connection with 2.5-16mm² cable sections.
  • This preinsulated sleeve is designed for the junction of low voltage overhead insulated conductors to other ones. The junction can be establish between two conductors of equal or unequal sections. All combinations of sections are possible.
  • IRO tube

    1,00
    The IRO tube is used outside to allow mechanical protection round electrical cables. The junction sleeve allows to connect two IRO tubes. The connection sleeve allows a connection between the sheath and the general protection box. The T-sleeve and the elbow allow connection and adaptation of the circuit of the tubes. The mounting bracket allows to set the sheath beside a facade.
  • These I.P.C. (Insulation Piercing Connector) are designed to establish a tap connection from a medium voltage conductor to another conductor of the same type.
  • This end connectors range is used for the connection of leading in cables to electrical equipment terminals (cutouts, electronic meters, ect). It is a universal solution to connect the connection cable and the meter terminals no matter what is the metal or the block nature. They can be fitted on copper or aluminum stranded or solid core conductors.
  • This end connectors range is used for the connection of leading in cables to electrical equipment terminals (cutouts, electronic meters, ect). It is a universal solution to connect the connection cable and the meter terminals no matter what is the metal or the block nature. The end connector can be fitted on sectoral or circular-shaped copper or aluminum stranded or solid core conductors. It provides class II protection using the double insulated colored tail, when equipped with the cover.
  • This end connectors range is used for the connection of leading in cables to electrical equipment terminals (cutouts, electronic meters, ect). It is a universal solution to connect the connection cable and the meter terminals no matter what is the metal or the block nature. The end connector can be fitted on sectoral or circular-shaped copper or aluminum stranded or solid core conductors. It provides class II protection using the double insulated colored tail, when equipped with the cover.
  • This I.P.C. (Insulation Piercing Connector) is designed for short-circuiting or earthing the low voltage A.B.C. (Aerial Bundled Conductors). It is also used for taking voltage measures. It comprises the connector and the socket.
  • These crimping tools are designed for the crimping of junction sleeves and lugs. They are available in 2 versions: - hydraulic type, - electro-hydraulic type.
  • These bolts and nuts are designed to fix MV/LV accessories.
  • This heat-shrinkable material is designed for low voltage applications in order to protect conductors and make them watertight. It is characterised by its insulating performances and its high resistivity to pollution and UV. It is retracted by blow torch heating.
  • This galvanised steel earth rod is used for the power networks earth system. The corrosion protection is ensured thanks to a hot dip galvanisation surface treatment. The reference Standard is EN 50 164-2.
  • This Gang Fuse Switch Disconnector (FSD) is a multi-phase device. It is installed at the top of a pole or on façade. It protects the overhead connection supplying one or more multi-phase customers, or, the low voltage circuit of a pole mounted transformer. It is designed to receive 160A fuse cartridge or 240A solid connecting links, size 00 (accordig to the IEC 269-2.1 standard).
  • This Gang Fuse Switch Disconnector (FSD) is a multi-phase device. It is installed at the top of a pole or on façade. It protects the overhead connection supplying one or more multi-phase customers, or, the low voltage circuit of a pole mounted transformer. It is designed to receive 160A fuse cartridge or 240A solid connecting links, size 00 (according to the IEC 269-2.1 standard).
  • This Gang Fuse Switch Disconnector (Gang FSD) is a multi-phase device. It is installed at the top of a pole or on façade. It protects the overhead connection supplying one or several multi-phase customers or the low voltage circuit of a pole mounted transformer. It is designed to receive 160A fuse cartridges or 240A solid connecting links, size 00 (according to the IEC 269-2.1 standard).
  • This Fuse Switch Disconnector (FSD) is a single phase device. It is installed at the top of pole or on façade. It protects the overhead connection supplying an individual customer and the low voltage network. It is designated to receive a 160A fuse cartridge or 240A maximum solid connecting link size 00 (according to the IEC 269-2.1 standard).
  • This Fuse Switch Disconnector (FSD) is a single phase device. It is installed at the top of pole or on façade. It protects the overhead connection supplying an individual customer and the low voltage network. It is designed to receive a neutral tube or a 100A maximum, size 22x58 fuse cartridge (according to the IEC 269-2.1 standard)
  • This Fuse Switch Disconnector (FSD) is a single phase device. It is installed at the top of pole or on façade. It protects the overhead connection supplying an individual customer and the low voltage network. It is designed to receive a neutral tube or 100A maximum, size 22x58 fuse cartridge (according to the IEC 269-2.1 standard).
  • This fuse switch connector is designed to receive a 10.3x38mm fuse cartridge or neutral tube. It is used to protect street light or insulated service conductors connected to the low voltage A.B.C. (Aerial Bundled Conductors) or bare line conductors. It is designed for 20A maximum fuse cartridge. It is used in no mechanical load situations.
  • This fuse switch connector is designed to receive a 22x58mm fuse cartridge or neutral tube. It is used to protect the insulated service conductors connected to a low voltage A.B.C. (Aerial Bundled Conductors). It is used in no mechanical load situations. Opening and closing of the cutout can be performed under a load of 63A maximum.
  • This Fuse Insulation Piercing Pit Connector (IPPC) is designed to receive a neutral tube, a mini-switch or a 100A maximum, size 22x58 fuse cartridge. It is used to connect a customer service line to an underground conductor. It is installed in a pit and can operate partially and temporary immersed in water. It is equipped with mechanical tightening terminals allowing its installation on a conductor using a simple spanner.
  • This cutout sleeve is designed to receive a 22x58 fuse cartridge, a neutral tube or a mini-switch. It is used in no mechanical load situations. It is equipped with mechanical tightening terminals allowing its installation using a simple spanner. Opening and closing of the cutout can be performed under a load of 63A maximum.
  • These low voltage fuses cartridges NH00, NH1 or NH2 are type gG. They are used as protection unit of the low voltage public electricity supply networks and works. It is installed in: - Low voltage switchboards of the public electricity supply substations, - Cutout boxes, inside or outside supply switches, - Switch cabinets for subsurface networks, - Metering boxes and cabinets for different uses
  • These gG fuses cartridges are designed to protect goods. They are implemented in a cutout sheltered from outside weather conditions.
  • These AD fuse cartridges are used together with the circuit-breaker installed on the individual service tap connection. They perform the cutoff for high short-circuit currents and there by extend the service life of the associated circuit-breaker, which is not overloaded up to the limit.
  • The concentric insulated service cable is used for the connection between the low-voltage network and the premise. It is designed to limit fraud and thus to reduce non-technical losses thanks to a peripheral neutral cable. Any unauthorised connection to this cable will create a short-circuit and will automatically cut off electricity supply. It is stretched overhead to a maximum range of 40m. The accessories enable to realise the fulfilment of the single phase or three phase concentric cable before performing a connection at the top of a pole or inside the cabinet. The kits ensure the insulation and the sealing of the anti-fraud conductor. The end connectors receive the fulfilment of the concentric cable and enable the leading-in cables connection to electrical equipment terminals. The tool for stripping is used to strip the cable in order to reconstitute and isolate the neutral for connection.
  • The 200A floor supply box allows 6 single-phase service connections or 2 three-phases service connections from a electrical column. It can be installed vertically or horizontally.
  • The flexible linking cable is used for the equipment wiring when the rigid stranded core or solid core conductor installation is too difficult.
  • The energy manager configuration is performed through a software available on PC or tablet. The last ten settings are kept in memory for a better suscriber follow up.
  • The energy manager is provided with an electronic regulator, controlling power and managing energy automatically without user / operator intervention. It is perfectly suitable for flat fee energy invoicing. It replaces the meter and cancels the requirement of consumption reading. The cabinet can be installed outside thanks to the UV resistant IP34 property. It is designed for a single phase connection.