This tape is designed to conduct the electricty into the earth system and to guarantee the default current runoff. If the copper gives an important electrical and the tinned coating protects from theft thanks to the non visible copper coating conductivity. The copper bonded steel offers a good economical alternative to copper. Furthermore Galvanized steel is an economical solution to coppered tinned steel and protect from the theft too. It has a good conductivity.
-
The REMIC module type RRCP offers a network outlet that can be cut (400 A function) or protected using maximum 200A fuses 115mm size 2 (200A function). It is installed on the M12 standardised connection terminals of the sets of bars supports. It is mainly used for supplying a collective or individual service with supervised power.
-
The fuse service module exists in 3 versions: 60A, 90A and 100A available in single or three phase kits depending on the model. In variation of the fused neutral, a triple neutral is possible. It is installed on the M12 standardized connection terminals of the set of bars support. It is used to tap a single or three phase service connection ensuring protection through fuses size 00 (60A and 90A modules) or 22x58 (100A module). The multitap connection module comprises 1 neutral and 3 phases. It allows a maximum of 3 single phase or 3 three-phase services to be connected. It is installed on the M12 standardized connection terminals of the set of bars support. It is mainly used when the AD fuses are installed in the customer premises.
-
The modular distribution box is designed to be equipped with devices that protect the customer installation. The 30 mA differential switches for two-phases are designed to protect persons by detecting insulation defects. The AC-type detected faults on the AC component. The A-type detected faults on the AC and DC components. The DC components faults can be produce by some electrical devices. The size of differntial swith is 2 modules. Subdivisional circuit breakers are designed to protect the circuits of the installation. The proposed materials are : - Neutral Phase 230V, - A type C trip curve according to EN 60898-1.
-
This end connectors range is used for the connection of leading in cables to electrical equipment terminals (cutouts, electronic meters, ect). It is a universal solution to connect the connection cable and the meter terminals no matter what is the metal or the block nature. They can be fitted on copper or aluminum stranded or solid core conductors.
-
The box with 3 outlets is designed to establish up to 6 single phase connections or up to 3 three phase connections at one point of the low voltage aerial bundled network. The box with 7 outlets is designed to establish the junction of 2 overhead networks and the tap contact of 6 single phase or three phase connections maximum. These boxes can be installed on a façade or a pole. They can also be used at the network end.