• This fuse switch connector is designed to receive a 10.3x38mm fuse cartridge or neutral tube. It is used to protect street light or insulated service conductors connected to the low voltage A.B.C. (Aerial Bundled Conductors) or bare line conductors. It is designed for 20A maximum fuse cartridge. It is used in no mechanical load situations.
  • This fuse switch connector is designed to receive a 22x58mm fuse cartridge or neutral tube. It is used to protect the insulated service conductors connected to a low voltage A.B.C. (Aerial Bundled Conductors). It is used in no mechanical load situations. Opening and closing of the cutout can be performed under a load of 63A maximum.
  • This Fuse Insulation Piercing Pit Connector (IPPC) is designed to receive a neutral tube, a mini-switch or a 100A maximum, size 22x58 fuse cartridge. It is used to connect a customer service line to an underground conductor. It is installed in a pit and can operate partially and temporary immersed in water. It is equipped with mechanical tightening terminals allowing its installation on a conductor using a simple spanner.
  • This cutout sleeve is designed to receive a 22x58 fuse cartridge, a neutral tube or a mini-switch. It is used in no mechanical load situations. It is equipped with mechanical tightening terminals allowing its installation using a simple spanner. Opening and closing of the cutout can be performed under a load of 63A maximum.
  • These low voltage fuses cartridges NH00, NH1 or NH2 are type gG. They are used as protection unit of the low voltage public electricity supply networks and works. It is installed in: - Low voltage switchboards of the public electricity supply substations, - Cutout boxes, inside or outside supply switches, - Switch cabinets for subsurface networks, - Metering boxes and cabinets for different uses
  • These gG fuses cartridges are designed to protect goods. They are implemented in a cutout sheltered from outside weather conditions.
  • These AD fuse cartridges are used together with the circuit-breaker installed on the individual service tap connection. They perform the cutoff for high short-circuit currents and there by extend the service life of the associated circuit-breaker, which is not overloaded up to the limit.
  • The concentric insulated service cable is used for the connection between the low-voltage network and the premise. It is designed to limit fraud and thus to reduce non-technical losses thanks to a peripheral neutral cable. Any unauthorised connection to this cable will create a short-circuit and will automatically cut off electricity supply. It is stretched overhead to a maximum range of 40m. The accessories enable to realise the fulfilment of the single phase or three phase concentric cable before performing a connection at the top of a pole or inside the cabinet. The kits ensure the insulation and the sealing of the anti-fraud conductor. The end connectors receive the fulfilment of the concentric cable and enable the leading-in cables connection to electrical equipment terminals. The tool for stripping is used to strip the cable in order to reconstitute and isolate the neutral for connection.
  • The 200A floor supply box allows 6 single-phase service connections or 2 three-phases service connections from a electrical column. It can be installed vertically or horizontally.
  • The flexible linking cable is used for the equipment wiring when the rigid stranded core or solid core conductor installation is too difficult.
  • The energy manager configuration is performed through a software available on PC or tablet. The last ten settings are kept in memory for a better suscriber follow up.
  • The energy manager is provided with an electronic regulator, controlling power and managing energy automatically without user / operator intervention. It is perfectly suitable for flat fee energy invoicing. It replaces the meter and cancels the requirement of consumption reading. The cabinet can be installed outside thanks to the UV resistant IP34 property. It is designed for a single phase connection.
  • This device is designed for shortcircuiting and earthing the low voltage A.B.C. (Aerial Bundled Conductors). It is connected to a connector for measures and short-circuiting (type CMCC). This equipment is used for earth system a low voltage A.B.C. (Aerial Bundled Conductor). It is connected on shortcircuiting device linked to CMCC connectors (for measures and shortcircuiting).
  • This earth tester is used as part of the earth system installation. It enables to perform the earth resistance measurements to control the system effectiveness.
  • The "C" shape connectors and jumper clamps are designed to connect two conductors. The mechanical and electrical connection is ensured thanks to crimping (U009) or thanks to a mechanical tightening wich can be removed (U020). The copper connector is designed to fix up an installation in case the conductor has been severed. The stainless steel fastening allows the product to be buried. The connector L260 is equipped with a shear head. The stainless steel kit comprises two tubular lugs (U030) as well as a nut and a bolt. It is designed to disconnect the earth system in order to perform earth resistance measurements. The cutting blade is designed to open the earth system during earth resistance measurements. It is rather used inside for a residential installation. The copper round terminal lug is used to connect bare copper conductors to copper terminals.
  • The cabinet is part of the installation check board. It ensures the connection individual principal cutout function. It is designed to receive fuse cartridges size 10.3x38, 14x51, 22x58 and DIN 00.
  • This copper earth electrode is used for the power networks earth system. When a deep installation is not possible, it gives an important contact area with the soil to discharge fault currents. The reference S tandard isEN 50 164-2.
  • This earth rod is used for the power networks earth system. The copper coating made by electrolytic process gives a resistance to corrosion as well as a good conductivity. The reference standards are EN 50 164-2 and EN 62 561-2. The brass clamp with stainless steel bolts is designed to establish a connection between the earth rod and the conductor. The cable can be fixed radially or axially through the "U" bolt clamp. The round connection clamp can be in bronze. These brass driving spikes and heads are designed to protect the earth rod during the installation. They enable to preserve the copper coating and its technical features. The taper coupling is made of brass. It allows the junction between two unthreaded earth rods with nominal diameter 16mm.
  • The warning tape enables to secure and delimit a work area on a construction site. The safety barrier enables to secure and delimit a work area on a construction site. The netting is made of stretch mesh and offers a high tensile strength allowing extension without any risk of deformation or tearing.
  • The sleeve is designed to ensure watertightness and insulation of bare fittings on low voltage network cables. It is designed for round or sectoral type conductors. The sheath is used to insulate the neutral conductor. Before the installation, lubricate the bare neutral conductor.
  • This cable sealing end is designed to ensure the watertightness of network and service stripped conductors ends. It is slid on the conductors and implemented without using flame. This cap is designed to ensure the watertightness of network and service cables conductors end. It can be used on cable drums. It is used exclusively without power.
  • Cable tie

    1,00
    The cable tie is designed to tighten the phase and neutral conductors in order to achieve correct installation. It is used to prevent the conductors from rubbing against accessories such as clamps.
  • The cable saddle (facade) is designed for fixing the low voltage A.B.C. (Aerial Bundled Conductors) on façades using neutral messenger or fully supported technology. A cable saddle is implemented every 30cm to ensure excellent fixing of the A.B.C. The wall mounting is quick and easy to implement. It is discreet and aesthetic. The cable saddle (pole) is used to fix cable trunking on poles. It is fixed using a strap and it is made of UV protected thermoplastic material. The N733 is sealed with a cable tie for 15 to 30mm diameter cables, the N734 for 30 to 50mm diameter cables, and the N735 for 50 to 90mm cables.
  • Cable

    1,00
    This cable is used pour earth systems. It is available in bare copper or insulated copper.