• This product is designed to ensure watertightness at the end of a network cable and to connect home device with peripheral neutral service cable. No tool is required for the installation.
  • The network module is available in 2 versions: - 50-240mm², - 50-150mm². It comprises one neutral terminal and three phase terminals. It is installed on the M12 standardized connection terminals of the sets of bars supports.
  • The fuse service module exists in 3 versions: 60A, 90A and 100A available in single or three phase kits depending on the model. In variation of the fused neutral, a triple neutral is possible. It is installed on the M12 standardized connection terminals of the set of bars support. It is used to tap a single or three phase service connection ensuring protection through fuses size 00 (60A and 90A modules) or 22x58 (100A module). The multitap connection module comprises 1 neutral and 3 phases. It allows a maximum of 3 single phase or 3 three-phase services to be connected. It is installed on the M12 standardized connection terminals of the set of bars support. It is mainly used when the AD fuses are installed in the customer premises.
  • The REMIC module type RRCP offers a network outlet that can be cut (400 A function) or protected using maximum 200A fuses 115mm size 2 (200A function). It is installed on the M12 standardised connection terminals of the sets of bars supports. It is mainly used for supplying a collective or individual service with supervised power.
  • TPC sheath

    1,00
    This sheath is used for the protection of underground cables. It is available in ring (with draw needle) or in bar. The junction sleeve allows connection between two ends of sheaths. The seperator allows to facilitate the installation of sheaths and to split each one. The sheath end cap allows to seal the sheath by closing its end.
  • This accessory is designed to short-circuit waiting networks without power. It is used to warn accidental powering at one end. It ensures cables watertightness.
  • This Fuse Insulation Piercing Pit Connector (IPPC) is designed to receive a neutral tube, a mini-switch or a 100A maximum, size 22x58 fuse cartridge. It is used to connect a customer service line to an underground conductor. It is installed in a pit and can operate partially and temporary immersed in water. It is equipped with mechanical tightening terminals allowing its installation on a conductor using a simple spanner.
  • These preinslated lugs with mechanical tightening are used to connect aerial aluminum or copper conductors, solid or stranded round core, to copper equipment terminals. They are to be used without mechanical load. They are made of tinned copper which allows compatibility to copper and aluminium. The connection of the conductor is ensured by one or two shear head screws, for optimal tightening.
  • Aerial sub-surface junction is designed to establish the connection from an underground network to a low voltage overhead network. They are implemented on overhead environment along a pole, under a mechanical protection as a conduit.
  • This mat is used to protect the fitter working area from contact voltage, during electrical work, without load in HV context and under load in LV one. Several models are available from class 0 to class 4. The insulating ladder protects the fitter from current voltage during electrical installation works.
  • This device is designed to perform a short-circuit and the earthing of a low voltage network A.B.C. (Aerial Bundled Conductors). It is connected to the MICHAUD 3-poles type pole-mounted Gang Fuse Switch Disconnector (Gang FSD).
  • The 200A floor supply box allows 6 single-phase service connections or 2 three-phases service connections from a electrical column. It can be installed vertically or horizontally.