This 2 outputs meter cabinet is a solution perfectly suitable for Rural Electrification (RE) and particularly Income Generating Activities (IGA's). It comprises an internal circuit breaker, a meter and a differential circuit breaker to ensure goods and people protection. It is equipped with an input through a large cable gland for power supply and 2 outputs: - An electrical outlet for simple access to energy, - Second outlet through a smaller cable gland and black domino terminal for home wiring. The whole set is pre-wired. Ideally, it can be installed inside the home or below a shelter.
-
The modular distribution box is designed to be equipped with devices that protect the customer installation. The 30 mA differential switches for two-phases are designed to protect persons by detecting insulation defects. The AC-type detected faults on the AC component. The A-type detected faults on the AC and DC components. The DC components faults can be produce by some electrical devices. The size of differntial swith is 2 modules. Subdivisional circuit breakers are designed to protect the circuits of the installation. The proposed materials are : - Neutral Phase 230V, - A type C trip curve according to EN 60898-1.
-
The RING connector is designed to establish a tap connection on low voltage underground networks. It is installed inside an underground box. It is used on a main cable, with synthetic insulation, of type: - Circular or sectoral, - Copper or aluminium, - Solid or stranded core. The underground box enables the tap connection from an underground network and for every conductors type (stranded, solid, multi-stranded, round or sectoral). It comprises the connector, the resin, the box and accessories according to the local standard.
-
The RING connector is designed to establish a tap connection on low voltage underground networks. It is installed inside an underground box. It is used on a main cable, with synthetic insulation, of type: - Circular or sectoral, - Copper or aluminium, - Solid or stranded core. The underground box enables the tap connection from an underground network. It makes possible the tap connection of every conductors type (stranded, solid, multi-stranded, round or sectoral). It comprises the connector, the resin, the box and accessories according to the local standard.
-
The RING connector is designed to establish a tap connection on low voltage underground networks. It is installed inside an underground box. It is used on a main cable, with synthetic insulation, of type: - Circular or sectoral, - Copper or aluminium, - Solid or stranded core The underground box enables the tap connection from an underground network. It makes possible the tap connection of every conductors type (stranded, solid, multi-stranded, round or sectoral). It comprises the connector, the resin, the box and accessories according to the local standard.
-
This connector is designed to connect a low voltage A.B.C. (Aerial Bundled Conductors) network to another low voltage aluminium alloy or copper bare conductors network. The section of the bare conductors is from 7 to 240mm² depending on the model. The section of the insulated cables is from 25 to 150mm² depending on the model.
-
This c onnector is de signed to connect a low voltage A.B.C. (Aerial Bundled Conductors) to another network of the same type or to a low voltage aluminium alloy or copper bare conductors network. In main line, the section of the insulated conductors is from 25 to 150mm² depending on the model, and is from 7 to 120mm² on bare conductors. In tap line, the section of the insulated conductors is from 25 to 70mm² and from 35 to 150mm² depending on the model.
-
This sleeve is designed to connect aluminium or copper conductors. It does not need the sectoral cores to be rounded before. It is implemented using a 13 or 17mm spanner. The electrical capacity is respectively 240mm² aluminium conductors (K191, K192), 150mm² aluminium or copper conductors (K193) and 95mm² aluminium or copper conductors (K189).